| Sign In | Join Free | My insurersguide.com |
|
Brand Name : KingPo
MOQ : 1
Place of Origin : China
Certification : ISO 17025 Calibration certificate
Price : To be quoted
Packaging Details : safety box
Delivery Time : 25~30 working days
Payment Terms : 100% TT in advance
Supply Ability : 3~5 units per month
Input power : AC 220V ±10% / 60Hz
IP Protection Class : IP20
Current/voltage detection sampling : four-wire connection
channel : optional
Channel control mode : independent
upper computer communication : TCP/IP
20V 10A Lithium Battery Testing Equipment Charge Discharge System
BTS-20V10A Battery Testing System
BTS-20V10A Battery Testing System , Battery Continuous charge , Battery Forced Discharge
Technical Parameter:
|
|
| |||||||||||||||||||||
| BTS-20V10A Battery tester |
| |||||||||||||||||||||
| Model Number: | BTS- | 20 | V | 10 | A | Battery tester | Material code: | CT-3008 | -20V10A | - | NA | - | P | |||||||||
| items | Parameter | |||||||||||||||||||||
| Input power | AC 220V ±10% / 60Hz | |||||||||||||||||||||
| Input active power | 2228 | W | ||||||||||||||||||||
| resolution ratio | AD:16bit;DA:12bit | |||||||||||||||||||||
| Input impedance | ≥1MΩ | |||||||||||||||||||||
| voltage | Constant voltage range | 100mV~20V |
| |||||||||||||||||||
| Minimum discharge voltage | 2.5V | |||||||||||||||||||||
| accuracy | ± 0.1% of FS | |||||||||||||||||||||
| stability | ± 0.1% of FS | |||||||||||||||||||||
| current | Output range/channel | 50mA~10A | ||||||||||||||||||||
| accuracy | ± 0.1% of FS | |||||||||||||||||||||
| Constant voltage cut-off current | 0.02A | |||||||||||||||||||||
| stability | ± 0.1% of FS | |||||||||||||||||||||
| power | Output range/channel | 200W | ||||||||||||||||||||
| stability | ± 0.2% of FS | |||||||||||||||||||||
| time | Current response time | maximum current rising time:20ms | ||||||||||||||||||||
| working step time range | ≤(365*24)h/working step | Time format00:00:00(h,min,s) | ||||||||||||||||||||
| Data record | Record data conditions | Minimum sampling time:1s | ||||||||||||||||||||
| Minimum sampling voltage:40mV | ||||||||||||||||||||||
| Minimum sampling current:20mA | ||||||||||||||||||||||
| Record frequency | 1Hz | |||||||||||||||||||||
| Charge | Charge mode | constant-current charge,constant-voltage charge,constant voltage and current charge | ||||||||||||||||||||
| cut-off conditions | Voltage,current,relative time,capacity,-△V | |||||||||||||||||||||
| discharge | Discharge mode | constant current discharge, constant watt discharge | ||||||||||||||||||||
| cut-off conditions | Voltage,current,relative time,capacity,-△V | |||||||||||||||||||||
| cycle | Loop test range | 1~65535 times | ||||||||||||||||||||
| Single cycle working steps | 254 | |||||||||||||||||||||
| Loop nest | Nested loop function,max 3 layers | |||||||||||||||||||||
| Protection | ● Data Protection | |||||||||||||||||||||
| ● off-line test | ||||||||||||||||||||||
| ● security conditions can be set including voltage upper/lower limit,current upper/lower limit and delay time | ||||||||||||||||||||||
| ●anti reverse connection | ||||||||||||||||||||||
| IP Protection Class | IP20 | |||||||||||||||||||||
| Channel feature | constant current and voltage source ;double closed-loop; |
| ||||||||||||||||||||
| Channel control mode | independent |
| ||||||||||||||||||||
| Current/voltage detection sampling | four-wire connection |
| ||||||||||||||||||||
| noise | <85dB |
| ||||||||||||||||||||
| data base | MySQL centralized management of test datas |
| ||||||||||||||||||||
| upper computer communication mode | TCP/IP |
| ||||||||||||||||||||
| Data output mode | EXCEL2003,2010,TXT |
| ||||||||||||||||||||
| Server disk Configuration | 500GB |
| ||||||||||||||||||||
| Server operating system | Windows 7 |
| ||||||||||||||||||||
| communication interface | ethernet |
| ||||||||||||||||||||
| Working environment requirement |
| |||||||||||||||||||||
| item | parameter |
| ||||||||||||||||||||
| working temp. range | 0℃~40℃(within25±10℃,ensured accuracy:precision drift0.005% of FS /℃) |
| ||||||||||||||||||||
| Storage temp. range | -10℃~50℃ |
| ||||||||||||||||||||
| Working environment relative humidity range | ≤70% RH(no water vapor condensation) |
| ||||||||||||||||||||
| Storage environment relative humidity range | ≤80% RH(no water vapor condensation) |
| ||||||||||||||||||||
| Clamp specification and size |
| |||||||||||||||||||||
| item | parameter |
| ||||||||||||||||||||
| Clamp type | Polymer clamp |
| ||||||||||||||||||||
| Pic |
|
|
|
| ||||||||||||||||||
| Alligator clamp | Polymer clamp | cable feet clamp |
| |||||||||||||||||||
| Pictures are for reference only,real objects shall prevail.Choose one |
| |||||||||||||||||||||
| Cabinet size/unit(W*D*H)(mm) | 12U(19”),600*600*740 |
| ||||||||||||||||||||
| Equipment pic |
|
| ||||||||||||||||||||
| Pictures are for reference only,real objects shall prevail. |
|
| ||||||||||||||||||||
Hot Tags: bts-20v10a battery testing system, China, manufacturers, suppliers, factory, custom, wholesale, UL507 PA160B Probe, Blowing Sand Tester KP-SCJB1000, IEC60065 Variable Frequency Power Supply, Digital Push And Pull Force Gauge, Tester For Impact By Small-Diameter Ball, Overcharge Discharge Lithium Battery Tester
|
|
20V 10A Lithium Battery Testing Equipment Charge Discharge System Images |